{"product_id":"convex-diffraction-grating-hyperspectral-meticulab","title":"Convex Diffraction Grating for Imaging Spectrometers | 0.2 - 16 micron Full Spectrum | Meticulab","description":"\u003c!-- ============================================================ --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- 核心卖点：全谱段覆盖、纳米级精度、全球极少数供应商            --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- ============================================================ --\u003e\n\u003cdiv style=\"font-family: 'Helvetica Neue', Arial, sans-serif; max-width: 860px; margin: 0 auto; padding: 10px 0;\"\u003e\n\u003c!-- 1. 价值主张副标题 --\u003e\n\u003ch2 style=\"font-size: 24px; font-weight: 300; color: #1a1a1a; border-left: 4px solid #0b1a33; padding-left: 15px; margin-top: 0;\"\u003eFull-Spectrum Precision: 0.2 to 16 Micron Convex Gratings for Next-Gen Hyperspectral Systems\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0791\/7695\/8204\/files\/applications.jpg?v=1784044366\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c!-- 2. 第一段：解决痛点 --\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.7; color: #333; margin: 20px 0;\"\u003eEvery imaging spectrometer relies on one critical component: the convex diffraction grating. For decades, this technology was controlled by a handful of institutions worldwide — until now. \u003cstrong\u003eMETICULAB™\u003c\/strong\u003e convex gratings deliver \u003cstrong\u003efull-spectrum coverage from 0.2 to 16 micron\u003c\/strong\u003e, achieving up to \u003cstrong\u003e5nm spectral resolution\u003c\/strong\u003e with nanometer-precision groove engraving. Whether you are developing satellite payloads, hyperspectral drones, or ground-based sensing systems, our gratings provide the performance edge you need.\u003c\/p\u003e\n\u003c!-- 3. 产品图片占位 --\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.7; color: #333; margin: 20px 0;\"\u003e\u003cimg style=\"width: 100%; max-width: 800px; height: auto; border-radius: 8px;\" alt=\"METICULAB Convex Diffraction Grating for Imaging Spectrometers\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0791\/7695\/8204\/files\/convex-grating-main.jpg?v=1783847786\"\u003e\u003c\/p\u003e\n\u003c!-- 4. 技术参数表格 --\u003e\n\u003ch3 style=\"font-size: 18px; font-weight: 600; color: #1a1a1a; margin: 30px 0 12px 0; border-bottom: 2px solid #eee; padding-bottom: 8px;\"\u003e📐 Technical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: #f9fafb; border: 1px solid #e2e8f0; font-size: 15px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px 16px; font-weight: 600; width: 35%; background: #f1f5f9;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px; width: 65%; font-weight: bold; color: #0b1a33;\"\u003eConvex Diffraction Grating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px 16px; font-weight: 600; background: #f1f5f9;\"\u003eSpectral Range\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px;\"\u003e0.2 to 16 micron (Full Spectrum: UV to LWIR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px 16px; font-weight: 600; background: #f1f5f9;\"\u003eSpectral Resolution\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px;\"\u003eUp to 5 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px 16px; font-weight: 600; background: #f1f5f9;\"\u003eGroove Density\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px;\"\u003e12.9 to 1662 lines per mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px 16px; font-weight: 600; background: #f1f5f9;\"\u003eGroove Width\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px;\"\u003eapprox 0.01 mm (Nanometer Precision)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px 16px; font-weight: 600; background: #f1f5f9;\"\u003eDiameter Range\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px;\"\u003e20mm to 138mm (Customizable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 12px 16px; font-weight: 600; background: #f1f5f9;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px;\"\u003eImaging Spectrometers, Hyperspectral Sensing, Remote Sensing, Aerospace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 16px; font-weight: 600; background: #f1f5f9;\"\u003eCustomization\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 16px;\"\u003eOEM Accepted, Small-Batch Manufacturing Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- 5. 分波段配置参考表（新增） --\u003e\n\u003ch3 style=\"font-size: 18px; font-weight: 600; color: #1a1a1a; margin: 30px 0 12px 0; border-bottom: 2px solid #eee; padding-bottom: 8px;\"\u003e📊 Standard Configurations\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: #f9fafb; border: 1px solid #e2e8f0; font-size: 15px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #0b1a33; color: #ffffff;\"\u003e\n\u003cth style=\"padding: 10px 16px; border: 1px solid #e2e8f0; text-align: left;\"\u003eBand\u003c\/th\u003e\n\u003cth style=\"padding: 10px 16px; border: 1px solid #e2e8f0; text-align: left;\"\u003eSpectral Range\u003c\/th\u003e\n\u003cth style=\"padding: 10px 16px; border: 1px solid #e2e8f0; text-align: left;\"\u003eGroove Density\u003c\/th\u003e\n\u003cth style=\"padding: 10px 16px; border: 1px solid #e2e8f0; text-align: left;\"\u003eDiameter\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0; background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 16px; border: 1px solid #e2e8f0; font-weight: 600;\"\u003eVIS\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 16px; border: 1px solid #e2e8f0;\"\u003e0.4 to 0.76 micron\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 16px; border: 1px solid #e2e8f0;\"\u003e82 lines per mm\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 16px; border: 1px solid #e2e8f0;\"\u003e28mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0; background: #f9fafb;\"\u003e\n\u003ctd style=\"padding: 10px 16px; border: 1px solid #e2e8f0; font-weight: 600;\"\u003eNIR\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 16px; border: 1px solid #e2e8f0;\"\u003e0.74 to 1.46 micron\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 16px; border: 1px solid #e2e8f0;\"\u003e87.7 lines per mm\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 16px; border: 1px solid #e2e8f0;\"\u003e27mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 16px; border: 1px solid #e2e8f0; font-weight: 600;\"\u003eSWIR\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 16px; border: 1px solid #e2e8f0;\"\u003e1.44 to 2.5 micron\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 16px; border: 1px solid #e2e8f0;\"\u003e30 lines per mm\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 16px; border: 1px solid #e2e8f0;\"\u003e56mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- 6. 核心优势模块 --\u003e\n\u003ch3 style=\"font-size: 18px; font-weight: 600; color: #1a1a1a; margin: 30px 0 12px 0; border-bottom: 2px solid #eee; padding-bottom: 8px;\"\u003e🌟 Why METICULAB™ Convex Gratings?\u003c\/h3\u003e\n\u003cul style=\"font-size: 15px; line-height: 1.8; color: #333; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull-Spectrum Dominance:\u003c\/strong\u003e Cover the entire optical range from 0.2 to 16 micron in a single platform. No gaps. No blind spots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNanometer-Precision Grooves:\u003c\/strong\u003e Groove width as fine as 0.01mm with densities up to 1662 lines per mm, achieving up to 5nm resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Top-Tier Technology:\u003c\/strong\u003e One of the very few manufacturers worldwide that master the complete convex grating production chain from design to small-batch manufacturing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProven in Critical Applications:\u003c\/strong\u003e Deployed in satellite payloads, hyperspectral drones, and ground-based sensing systems where reliability is non-negotiable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Customization:\u003c\/strong\u003e Diameters from 20mm to 138mm, groove densities from 12.9 to 1662 lines per mm — tailored to your optical design.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- 7. 产品图片（原理图占位） --\u003e\n\u003cp style=\"font-size: 16px; line-height: 1.7; color: #333; margin: 20px 0;\"\u003e\u003cimg style=\"width: 100%; max-width: 800px; height: auto; border-radius: 8px;\" alt=\"METICULAB Convex Grating Groove Structure Schematic - Nanometer Precision Engraving\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0791\/7695\/8204\/files\/convex-grating-schematic.jpg?v=1783847786\"\u003e\u003c\/p\u003e\n\u003c!-- 8. 典型应用 --\u003e\n\u003ch3 style=\"font-size: 18px; font-weight: 600; color: #1a1a1a; margin: 30px 0 12px 0; border-bottom: 2px solid #eee; padding-bottom: 8px;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0791\/7695\/8204\/files\/01_sky.jpg?v=1784044060\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0791\/7695\/8204\/files\/02_integration_system.jpg?v=1784044074\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0791\/7695\/8204\/files\/03.jpg?v=1784044079\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0791\/7695\/8204\/files\/04.jpg?v=1784044082\" alt=\"\"\u003e🛰️ Applications\u003c\/h3\u003e\n\u003cp style=\"font-size: 15px; color: #555;\"\u003eImaging Spectrometers • Hyperspectral Sensing Systems • Remote Sensing Satellites • Aerospace Payloads • Environmental Monitoring • Precision Agriculture • Defense and Security • Research Institutions\u003c\/p\u003e\n\u003c!-- 9. FAQ --\u003e\n\u003ch3 style=\"font-size: 18px; font-weight: 600; color: #1a1a1a; margin: 30px 0 12px 0; border-bottom: 2px solid #eee; padding-bottom: 8px;\"\u003e❓ Frequently Asked Questions\u003c\/h3\u003e\n\u003cdiv style=\"font-size: 15px; color: #333; line-height: 1.8;\"\u003e\n\u003cp style=\"margin: 0 0 4px 0; font-weight: 600;\"\u003eQ1: What is the minimum order quantity?\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 16px 0; padding-left: 16px; color: #555;\"\u003eA: MOQ is 1 piece for standard models to support your testing and validation. Volume orders receive flexible pricing.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 4px 0; font-weight: 600;\"\u003eQ2: Can you provide custom groove densities or diameters?\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 16px 0; padding-left: 16px; color: #555;\"\u003eA: Yes. We support 12.9 to 1662 lines per mm and diameters from 20mm to 138mm. Contact us with your specifications.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 4px 0; font-weight: 600;\"\u003eQ3: What is the typical lead time?\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 16px 0; padding-left: 16px; color: #555;\"\u003eA: Standard models within 30 working days; custom models within 45 working days after order confirmation.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 4px 0; font-weight: 600;\"\u003eQ4: Are these gratings suitable for aerospace applications?\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 16px 0; padding-left: 16px; color: #555;\"\u003eA: Yes. Our gratings are designed for extreme operating temperatures and have been deployed in satellite payloads and remote sensing systems.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 4px 0; font-weight: 600;\"\u003eQ5: What export compliance documentation is required?\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 0 0; padding-left: 16px; color: #555;\"\u003eA: Buyers must provide an End-User and End-Use Statement for export license application. Our team will guide you through the process.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- 10. 品牌底部与联系方式 --\u003e\n\u003cdiv style=\"background: #0b1a33; color: #ffffff; padding: 22px 28px; border-radius: 12px; margin-top: 30px; text-align: center;\"\u003e\n\u003cp style=\"font-weight: bold; color: #f5d98f; margin-bottom: 5px;\"\u003eMETICULAB™ — Precision Lab Solutions\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; margin-bottom: 10px;\"\u003e📧 \u003cstrong\u003echoikyuc@gmail.com\u003c\/strong\u003e  |  📞 +82-10-3988-4813  |  🌐 www.meticulab.net\u003c\/p\u003e\n\u003cdiv style=\"font-size: 13px; color: #b8ccdd;\"\u003eWhatsApp \u0026amp; KakaoTalk Available\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- 11. 底部免责声明 --\u003e\n\u003cp style=\"font-size: 12px; color: #7a8fa3; border-top: 1px solid #edf2f7; padding-top: 16px; margin-top: 18px; text-align: center; font-style: italic;\"\u003eMETICULAB™ is a premium laboratory technology brand. All products undergo rigorous quality verification before international dispatch. Export compliance documentation may be required for this product — contact us for assistance.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"METICULAB","offers":[{"title":"Default Title","offer_id":49906082447612,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0791\/7695\/8204\/files\/convex_grating_0_3.png?v=1784044717","url":"https:\/\/meticulab.net\/de\/products\/convex-diffraction-grating-hyperspectral-meticulab","provider":"METICULAB","version":"1.0","type":"link"}